Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Rev. bras. enferm ; 73(5): e20180921, 2020. tab
Artigo em Inglês | LILACS, BDENF | ID: biblio-1115360

RESUMO

ABSTRACT Objectives: to analyze the mean direct cost and peripheral venous access length outcomes using devices over needle with and without extension. Methods: quantitative, exploratory-descriptive research. Venous punctures and length of the devices were followed. The mean direct cost was calculated by multiplying the time (timed) spent by nursing professionals by the unit cost of labor, adding to the cost of materials. Results: the total mean direct cost of using devices "with extension" (US$ 9.37) was 2.9 times the cost of using devices "without extension" (US$ 4.50), US$ 7.71 and US$ 2.66, respectively. Totaling 96 hours of stay, the "device over needle with extension" showed a lower occurrence of accidental loss. Conclusions: the use of the "device over needle with extension", despite its higher mean direct cost, was more effective in favoring adequate length of peripheral venous access.


RESUMEN Objetivos: analizar el costo directo promedio y los resultados de permanencia del acceso venoso periférico, utilizando dispositivos de aguja con y sin extensión. Métodos: investigación cuantitativa, exploratoria descriptiva. Se siguieron los pinchazos venosos y el tiempo de permanencia de los dispositivos. El costo directo promedio se calculó multiplicando el tiempo (cronometrado) dedicado por los profesionales de enfermería por el costo unitario de la mano de obra, lo que se suma al costo de los materiales. Resultados: el costo directo promedio total de usar dispositivos "extendidos" (US$ 9,37) fue 2,9 veces el costo de usar dispositivos "no extendidos" (US$ 4,50) de materiales, US$ 7.71 y US$ 2.66, respectivamente. Con un total de 96 horas de estadía, el "dispositivo de aguja extendida" mostró una menor ocurrencia de pérdida accidental. Conclusiones: a pesar del costo directo promedio más alto, el uso de un "dispositivo de aguja extendida" fue más efectivo para favorecer un tiempo de acceso venoso periférico adecuado.


RESUMO Objetivos: analisar o custo direto médio e os desfechos de permanência de acesso venoso periférico, utilizando dispositivos sobre agulha com e sem extensão. Métodos: pesquisa quantitativa, exploratório-descritiva. Acompanharam-se as punções venosas e o tempo de permanência dos dispositivos. Calculou-se o custo direto médio multiplicando-se o tempo (cronometrado) despendido por profissionais de enfermagem pelo custo unitário da mão de obra, somando-se ao custo dos materiais. Resultados: o custo direto médio total do uso de dispositivo "com extensão" (US$ 9,37) foi 2,9 vezes do que o custo do uso de dispositivo "sem extensão" (US$ 4,50), destacando-se os custos dos materiais, US$ 7,71 e US$ 2,66, respectivamente. Totalizando 96 horas de permanência, o "dispositivo sobre agulha com extensão" apresentou menor ocorrência de perda acidental. Conclusões: o uso do "dispositivo sobre agulha com extensão", apesar do maior custo direto médio, foi mais eficaz para favorecer o adequado tempo de permanência do acesso venoso periférico.


Assuntos
Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cateterismo Periférico/economia , Cateterismo Periférico/normas , Avaliação de Resultados em Cuidados de Saúde/normas , Cateterismo Periférico/estatística & dados numéricos , Avaliação de Resultados em Cuidados de Saúde/estatística & dados numéricos , Custos e Análise de Custo , Agulhas/economia , Agulhas/normas , Agulhas/estatística & dados numéricos
3.
Braz. J. Pharm. Sci. (Online) ; 55: e18148, 2019. tab, graf, ilus
Artigo em Inglês | LILACS | ID: biblio-1039038

RESUMO

According to Anvisa risk rating, hypodermic needles offer medium risk to the user's health. This study discussed the importance of the corrosion resistance test in tubes of hypodermic needles, in the product quality control. A review of cannulas of hypodermic needles was carried out according to ISO 9626:2003 and 9259:1997 ABNT NBR. For the results evaluation, a scale which classifies the extent of corrosion was adjusted. 174 samples of PNI needles from 17 States and 9 different record holders were analyzed. According to the methodology of ISO 9626:2003, 100% of the samples were considered satisfactory. However, in accordance with the methodology of ISO 9259:1997, 97.1% of the samples were rejected. Irregularities can lead to impairment of product quality, resulting in risks to the consumer's health. Since 2011 the product has undergone certification, so it is necessary to reflect on the importance of corrosion resistance testing and mandatory certification for health monitoring.


Assuntos
Controle de Qualidade , Corrosão , Agulhas/normas , Vigilância de Produtos Comercializados , Brasil/etnologia , Cromo/análise , Cânula , Legislação como Assunto/normas
4.
Arq. bras. cardiol ; 110(6): 568-576, June 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-950179

RESUMO

Abstract Background: The cardiac hypertrophy (CH) model for mice has been widely used, thereby providing an effective research foundation for CH exploration. Objective: To research the effects of CH modeling under abdominal aortic constriction (AAC) using different needles and weights in mice. Methods: Four needles with different external diameters (0.35, 0.40, 0.45, and 0.50 mm) were used for AAC. 150 male C57BL/6 mice were selected according to body weight (BW) and divided into 3 weight levels: 18 g, 22 g, and 26 g (n = 50 in each group). All weight levels were divided into 5 groups: a sham group (n = 10) and 4 AAC groups using 4 ligation intensities (n = 10 per group). After surgery, survival rates were recorded, echocardiography was performed, hearts were dissected and used for histological detection, and data were statistically analyzed, P < 0.05 was considered statistically significant. Results: All mice died in the following AAC groups: 18g/0.35 mm, 22 g/0.35 mm, 26 g/0.35 mm, 22 g/0.40 mm, and 26 g/0.40 mm. All mice with AAC, those ligated with a 0.50-mm needle, and those that underwent sham operation survived. Different death rates occurred in the following AAC groups: 18 g/0.40 mm, 18 g/0.45 mm, 18 g/0.50 mm, 22 g/45 mm, 22 g/0.50 mm, 26 g/0.45 mm, and 26 g/0.50 mm. The heart weight/body weight ratios (5.39 ± 0.85, 6.41 ± 0.68, 4.67 ± 0.37, 5.22 ± 0.42, 4.23 ± 0.28, 5.41 ± 0.14, and 4.02 ± 0.13) were significantly increased compared with those of the sham groups for mice with the same weight levels. Conclusion: A 0.45-mm needle led to more obvious CH than did 0.40-mm and 0.50-mm needles and caused extraordinary CH in 18-g mice.


Resumo Fundamentos: O modelo de hipertrofia cardíaca (HC) para ratos foi amplamente utilizado, proporcionando assim uma base de pesquisa efetiva para a exploração de HC. Objetivo: pesquisar os efeitos do modelamento de HC sob constrição da aorta abdominal (CAA) usando diferentes agulhas e pesos em ratos. Métodos: foram utilizadas quatro agulhas com diâmetros externos diferentes (0,35, 0,40, 0,45 e 0,50 mm) para CAA. Foram selecionados 150 ratos C57BL / 6 machos de acordo com o peso corporal (PC) e divididos em 3 níveis de peso: 18 g, 22 g e 26g (n = 50 em cada grupo). Todos os níveis de peso foram divididos em 5 grupos: um grupo sham (n = 10) e 4 grupos CAA usando 4 intensidades de ligadura (n = 10 por grupo). Após a cirurgia, foram registradas as taxas de sobrevivência, foi realizada ecocardiografia, os corações foram dissecados e utilizados para detecção histológica, e os dados foram analisados estatisticamente, p < 0,05 foi considerado estatisticamente significante. Resultados: Todos os ratos morreram nos seguintes grupos de CAA: 18 g/0,35 mm, 22 g/0,35 mm, 26 g/0,35 mm, 22 g/0,40 mm e 26 g/0,40 mm. Todos os ratos com CAA, aqueles ligados com uma agulha de 0,50 mm, e aqueles que sofreram operação sham sobreviveram. Ocorreram diferentes taxas de mortalidade nos seguintes grupos de CAA: 18 g/0,40 mm, 18 g/0,45 mm, 18 g/0,50 mm, 22 g/45 mm, 22 g/0,50 mm, 26 g/0,45 mm e 26 g/0,50 mm. As proporções de peso do coração/peso corporal (5,39 ± 0,85, 6,41 ± 0,68, 4,67 ± 0,37, 5,22 ± 0,42, 4,23 ± 0,28, 5,41 ± 0,14 e 4,02 ± 0,13) aumentaram significativamente em comparação com os grupos sham para ratos com os mesmos níveis de peso. Conclusão: uma agulha de 0,45mm levou a HC mais óbvia do que as agulhas de 0,40 mm e 0,50mm e causou HC extraordinária em ratos de 18 g.


Assuntos
Animais , Masculino , Aorta Abdominal , Peso Corporal , Cardiomegalia/etiologia , Modelos Animais de Doenças , Agulhas/normas , Valores de Referência , Fatores de Tempo , Ecocardiografia , Distribuição Aleatória , Reprodutibilidade dos Testes , Cardiomegalia/patologia , Constrição , Ligadura/instrumentação , Camundongos Endogâmicos C57BL
5.
Clinics ; 73: e261, 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-890756

RESUMO

Our aim in this study was to compare the efficiency of 25G versus 22G needles in diagnosing solid pancreatic lesions by EUS-FNA. We performed a systematic review and meta-analysis. Studies were identified in five databases using an extensive search strategy. Only randomized trials comparing 22G and 25G needles were included. The results were analyzed by fixed and random effects. A total of 504 studies were found in the search, among which 4 randomized studies were selected for inclusion in the analysis. A total of 462 patients were evaluated (233: 25G needle/229: 22G needle). The diagnostic sensitivity was 93% for the 25G needle and 91% for the 22G needle. The specificity of the 25G needle was 87%, and that of the 22G needle was 83%. The positive likelihood ratio was 4.57 for the 25G needle and 4.26 for the 22G needle. The area under the sROC curve for the 25G needle was 0.9705, and it was 0.9795 for the 22G needle, with no statistically significant difference between them (p=0.497). Based on randomized studies, this meta-analysis did not demonstrate a significant difference between the 22G and 25G needles used during EUS-FNA in the diagnosis of solid pancreatic lesions.


Assuntos
Humanos , Pâncreas/patologia , Neoplasias Pancreáticas/patologia , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/instrumentação , Agulhas/normas , Neoplasias Pancreáticas/diagnóstico por imagem , Funções Verossimilhança , Ensaios Clínicos Controlados Aleatórios como Assunto , Sensibilidade e Especificidade , Eficiência , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/normas , Confiabilidade dos Dados
7.
Rio de Janeiro; s.n; 20160000. 57 p. ilus, graf.
Tese em Português | BDENF, LILACS | ID: biblio-1026234

RESUMO

Em função da inserção das Novas Tecnologias da Informação e Comunicação, na prática da Enfermagem, notamos que esta pode ser uma importante ferramenta de aprendizado, podendo contribuir para uma atuação da Equipe de Enfermagem mais eficaz. Logo, o Objeto de Estudo da presente pesquisa foi a multimídia interativa com vistas à adequada utilização de materiais perfurocortantes com dispositivo de segurança durante a punção venosa periférica. O objetivo central foi desenvolver uma multimídia interativa com vistas à adequada utilização de materiais perfurocortantes com dispositivo de segurança. Metodologia: o método adotado foi o quanti-qualitativo, sendo um estudo do tipo observacional. Resultados: 1- No que se refere ao momento da punção venosa periférica, notamos que embora a recomendação para higienização das mãos seja mandatória e que esta deve anteceder qualquer procedimento a ser realizado, apenas 20% dos participantes o fizeram antes da punção venosa periférica e; 2 - Na última etapa do procedimento realizado, o dado que nos chama atenção é que 80% dos participantes não realizaram o cálculo para a infusão dos medicamentos, realizando a infusão inicial de forma aleatória. Conclusão: Foi identificada a necessidade de uma nova abordagem específica referente ao treinamento de perfurocortantes com dispositivo de segurança, uma vez que com o desenvolvimento da nossa multimídia proposta, percebemos que é viável a realização e construção de outras tecnologias da informação


Due to the integration of New Technologies of Information and Communication in the nursing practice, we note that this can be an important learning tool and can contribute to a performance of nursing staff more effective. Thus, the study object of this research was to interactive multimedia aimed at the proper use of sharps with safety device for peripheral venipuncture. The Main Objective was to develop an interactive multimedia aimed at the proper use of sharps with safety device. Methods: the method adopted was the quantitative and qualitative, being a study of observational type. Results: As regards the time of peripheral venous puncture, note that although the recommendation for hand hygiene is mandatory and that this should precede any procedure to be performed, only 20% of participants did before venous puncture and; 2 - In the last step of the procedure performed, the data that draws our attention is that 80% of participants did not perform the calculation for the infusion of drugs, carrying out the initial infusion randomly. Conclusion: it was identified the need for a new approach for the specific training of sharps with safety device, once with the development of our multimedia proposal, we realized that it is feasible the realization and construction of other information technologies


Assuntos
Humanos , Masculino , Feminino , Infusões Intravenosas , Acidentes de Trabalho/prevenção & controle , Aplicativos Móveis/tendências , Seringas/normas , Tecnologia Educacional , Segurança do Paciente , Agulhas/normas
8.
Acta cir. bras ; 30(3): 216-221, 03/2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-741032

RESUMO

PURPOSE: To evaluate the changes of contractility and reactivity in isolated lymphatics from hemorrhagic shock rats with resuscitation. METHODS: Six rats in the shock group suffered hypotension for 90 min by hemorrhage, and resuscitation with shed blood and equal ringer's solution. Then, the contractility of lymphatics, obtained from thoracic ducts in rats of the shock and sham groups, were evaluated with an isolated lymphatic perfusion system using the indices of contractile frequency (CF), tonic index (TI), contractile amplitude (CA) and fractional pump flow (FPF). The lymphatic reactivity to substance P (SP) was evaluated with the different volume of CF, CA, TI and FPF between pre- and post-treatment of SP at different concentrations. RESULTS: The CF, FPF, and TI of lymphatics obtained from the shocked rats were significantly decreased than that of the sham group. After SP stimulation, the ∆CF (1×10-8, 3×10-8, 1×10-7, 3×10-7 mol/L), ∆FPF (1×10-8, 3×10-8, 1×10-7 mol/L), and ∆TI (1×10-8 mol/L) of lymphatics in the shock group were also obviously lower compared with the sham group. In addition, there were no statistical differences in CA and ∆CA between two groups. CONCLUSION: Lymphatic contractility and reactivity to substance P appears reduction following hemorrhagic shock with resuscitation. .


Assuntos
Humanos , Fidelidade a Diretrizes , Mielografia/normas , Neurorradiografia/normas , Neurorradiografia/estatística & dados numéricos , Guias de Prática Clínica como Assunto , Radiologia/normas , Punção Espinal/normas , Congressos como Assunto , Pesquisas sobre Atenção à Saúde , Internacionalidade , Máscaras/normas , Máscaras/estatística & dados numéricos , Mielografia/estatística & dados numéricos , Agulhas/normas , Agulhas/estatística & dados numéricos , Médicos/estatística & dados numéricos , Radiologia/estatística & dados numéricos , Punção Espinal/estatística & dados numéricos
9.
Rev. bras. cir. plást ; 27(3): 478-481, jul.-set. 2012. ilus
Artigo em Inglês, Português | LILACS | ID: lil-668154

RESUMO

O tratamento cirúrgico apresentado neste artigo tem inovações táticas e torna o procedimento pouco agressivo. O objetivo é demonstrar uma maneira diferente de executar a suspensão do terço médio da face. O procedimento é realizado com agulhas semicirculares tipo Stocchero, com passagem de fio de náilon 2.0 no plano subcutâneo, na altura da borda anterior da glândula parótida, e fixação do fio na fáscia temporal. Foram operados com emprego desse método 49 pacientes, com obtenção de bons resultados estéticos. Em um paciente, houve necessidade de executar uma cicatriz pré-auricular, para acomodação da pele. O método é seguro, simples, não necessita de internação hospitalar, evita uma cicatriz pré-auricular e o resultado oferece boa satisfação aos pacientes.


The surgical treatment presented here involves technical innovations, making it a less-aggressive procedure. The goal is to demonstrate a different way of executing a suspension of the skin in the medial third of the face. The procedure is performed with semi-circular Stocchero needles with the passage of a 2-0 nylon thread through the subcutaneous plane at the anterior edge of the parotid gland and fixation to the temporal fascia. A total of 49 patients were operated on using this method with good aesthetic results. One patient required a pre-auricular incision to accommodate the skin. This method is safe, simple, does not require hospital inpatient admission, avoids a pre-auricular scar, and provides satisfactory results.


Assuntos
Humanos , Feminino , Adulto , Pessoa de Meia-Idade , História do Século XXI , Glândula Parótida , Rejuvenescimento , Instrumentos Cirúrgicos , Ritidoplastia , Técnicas Cosméticas , Procedimentos de Cirurgia Plástica , Estética , Face , Agulhas , Glândula Parótida/cirurgia , Rejuvenescimento/psicologia , Instrumentos Cirúrgicos/normas , Instrumentos Cirúrgicos/ética , Ritidoplastia/métodos , Técnicas Cosméticas/normas , Procedimentos de Cirurgia Plástica/métodos , Face/cirurgia , Agulhas/normas , Agulhas/ética
10.
Rev. bras. anestesiol ; 58(6): 569-581, nov.-dez. 2008. ilus, tab
Artigo em Inglês, Português | LILACS | ID: lil-497045

RESUMO

JUSTIFICATIVA E OBJETIVOS: Comparar a qualidade e a segurança da anestesia retrobulbar (ARB) para tratamento de catarata por facoemulsificação utilizando agulhas de dois diferentes tamanhos: 25 x 0,70 mm ou 20 x 0,55 mm. MÉTODOS: Seleção prospectiva de candidatos a bloqueio oftálmico para tratamento de catarata por facoemulsificação. Após sedação e monitorização padronizada, foi realizada anestesia retrobulbar (ARB) em punção única ínfero-lateral com 4 mL de ropivacaína 1 por cento, contendo hialuronidase. No Grupo I (GI) a agulha utilizada foi de 25 x 0,70 mm e no Grupo II (GII), de 20 x 0,55 mm. Em um paciente de cada grupo foram realizadas tomografias computadorizadas no momento da realização do bloqueio oftálmico e após cinco minutos da administração da solução anestésica com contraste radiológico. A mobilidade ocular foi avaliada após três, cinco e dez minutos. Por meio de um questionário padronizado, foram comparadas a incidência de complicações entre os grupos, a satisfação dos pacientes e cirurgiões. RESULTADOS: Foram avaliados 54 pacientes adultos (27 por grupo). Nenhum paciente relatou dor ou percepção luminosa intra-operatória. O procedimento anestésico foi considerado muito bom (MB) ou excelente (E) em 96,30 por cento dos casos nos dois grupos. A mesma avaliação foi feita por 100 por cento dos pacientes. Não houve diferença na necessidade de repetição do bloqueio entre os grupos (p = 1,0). O GI apresentou menor mobilidade ocular aos 3 minutos (p = 0,03). Observou-se o posicionamento da agulha em posição retrobulbar intraconal em ambos os grupos. A dispersão anestésica foi similar entre os grupos aos 5 minutos. CONCLUSÃO: A ARB realizada com a agulha de 20 × 0,55 mm, em punção única ínfero-lateral, utilizando baixas doses de anestésicos, se apresenta como uma opção eficaz e segura para tratamento de catarata por facoemulsificação.


BACKGROUND AND OBJECTIVES: The objective of this study was to compare the quality and safety of retrobulbar block for the treatment of cataracts by phacoemulsification using needles of different sizes: 27 × 0.70 mm and 20 × 0.55 mm. METHODS: Candidates for ophthalmic block for the treatment of cataracts by phacoemulsification were selected prospectively. After sedation and standardized monitoring, a retrobulbar block with 4 mL of 1 percent ropivacaine containing hyaluronidase was performed with a single inferolateral puncture. In Group I (GI), the 25 × 0.70 mm needle was used, while in Group II (GII) a 20 × 0.55 mm needle was used. All patients had a CT scan at the time of the blockade and five minutes after the administration of the anesthetic solution with radiologic contrast. Ocular mobility was assessed after three, five, and ten minutes. The incidence of complications in both groups and the satisfaction of patients and surgeons were compared by applying a standardized questionnaire. RESULTS: Fifty-four adult patients were evaluated (27 per group). Patients did not complain of intraoperative pain or perception of light. The anesthetic procedure was considered very good (VG) or excellent (E) in 96.3 percent of the cases in both groups. All patients were subjected to the same assessment. The need of block repetition between both groups did not differ (p = 1.0). Patients in GI showed decreased ocular mobility at 3 minutes (p = 0.03). The intraconal retrobulbar placement of the needle was observed on both groups. Anesthetic dispersion at 5 minutes was similar in the two groups. CONCLUSIONS: Retrobulbar block with a single inferolateral puncture with a 20 × 0.55 mm needle, using low doses of anesthetics, is an effective and safe option for the treatment of cataracts by phacoemulsification.


JUSTIFICATIVA Y OBJETIVOS: Comparar la calidad y la seguridad de la anestesia retrobulbar (ARB) para tratamiento de catarata por facoemulsificación, utilizando agujas de dos diferentes tamaños: 25 x 0,70 mm o de 20 x 0,55 mm. MÉTODOS: Selección prospectiva de candidatos a bloqueo oftálmico para tratamiento de catarata por facoemulsificación. Después de la sedación y monitoreo estandarizado, se realizó anestesia retrobulbar (ARB) en punción única ínfero-lateral con 4 mL de ropivacaina 1 por ciento, con hialuronidasa. En el Grupo I (GI), la aguja utilizada fue de 25 x 0,70 mm y en el Grupo II (GII), de 20 x 0,55 mm. En un paciente de cada grupo fueron realizadas tomografías computadorizadas al momento de la realización del bloqueo oftálmico y después de cinco minutos de la administración de la solución anestésica con contraste radiológico. La movilidad ocular se evaluó después de tres, cinco y diez minutos. A través de un cuestionario estandarizado, se compararon la incidencia de complicaciones entre los grupos, y la satisfacción de los pacientes y de los cirujanos. RESULTADOS: Fueron evaluados 54 pacientes adultos (27 por grupo). Ningún paciente relató dolor o percepción luminosa intraoperatoria. El procedimiento anestésico fue considerado muy bueno (MB) o excelente (E) en un 96,30 por ciento de los casos en los dos grupos. La misma evaluación se hizo en un 100 por ciento de los pacientes. No hubo diferencia en la necesidad de repetición del bloqueo entre los grupos (p = 1,0). El GI presentó menor movilidad ocular a los 3 minutos (p = 0,03). Se observó el posicionamiento de la aguja en posición retrobulbar intraconal en los dos grupos. La dispersión anestésica fue similar entre los grupos a los 5 minutos. CONCLUSIÓN: La ARB realizada con la aguja de 20 x 0,55mm, en punción única ínfero-lateral, utilizando bajas dosis de anestésicos, se presenta como una opción eficaz y segura para el tratamiento de catarata por facoemulsificación.


Assuntos
Humanos , Agulhas/normas , Anestesia por Condução/métodos , Facoemulsificação/instrumentação , Extração de Catarata
12.
Indian J Med Sci ; 2001 Jun; 55(6): 313-8
Artigo em Inglês | IMSEAR | ID: sea-66854

RESUMO

Out of hundred syringes and hundred needles (both presterile, disposable) tested, 41 syringes (41%) and 6 needles (6%) showed aerobic growth. Forty of the above syringes were tested simultaneously for fungi and anaerobes. Fungi isolated were 5.7% and no anaerobe was grown. Fifty glass syringes and fifty needles autoclaved in the departmental laboratory served as controls and did not show any growth. As a preventive measure, proper disposal of used disposable material should be made mandatory so that it does not find its way into the market. Or has the time come to switch back to the former conventional practice of using in house autoclaved articles?


Assuntos
Equipamentos Descartáveis/normas , Contaminação de Equipamentos , Humanos , Índia , Eliminação de Resíduos de Serviços de Saúde/normas , Agulhas/normas , Esterilização/normas , Seringas/normas
13.
Pesqui. odontol. bras ; 14(3): 294-9, jul.-set. 2000. tab
Artigo em Português | LILACS, BBO | ID: lil-271820

RESUMO

Foram avaliadas neste trabalho agulhas anestésicas odontológicas descartáveis, comercializadas no Brasil no segundo semestre de 1997, quanto às medidas: comprimento da cânula, da porçäo que perfura o tubete e da porçäo que permanece no interior do adaptador plástico e diâmetros externo e interno. A resistência à corrosäo da cânula e as informaçöes da embalagem (caixa e protetor) também foram avaliadas. Os resultados foram comparados com as normas Internacional (ISO), Americana (ANSI/ADA) e Francesa (NF). Foram observadas variaçöes, näo havendo uma só marca que estivesse de acordo com qualquer das normas, para totas as medidas. Todas as agulhas atingiram as especificaçöes do teste de corrosäo. Algumas embalagens mostraram conteúdo de informaçäo incompleto e uma marca estava sendo vendida sem prazo de validade. Alguns protetores näo permitiam identificar a violaçäo do lacre, quando isto ocorria. Estes resultados demonstram a necessidade de se estabelecerem normas brasileiras, para regulamentar a produçäo e venda de agulhas odontológicas no país


Assuntos
Agulhas/classificação , Agulhas/normas , Controle de Qualidade
14.
Rev. méd. cient. San Gabriel ; 3(1): 22-3, 1996. tab
Artigo em Espanhol | LILACS | ID: lil-238423

RESUMO

Objetivo: El estudio se realizo en forma prospectiva longitudinal comparativo en 100 pacientes sometidos a cirugia programada, cirugia general, urològia, proctològica y traumatològica bajo anestesia intradural. Material y Mètodo: La edad media de los pacientes fue de 33,71 + 13,4 años. la anestesia intradural se efectùo con aguja Becton Dickinson de calibre 21 punta Quinke para el grupo 1 y calibre 25 para el grupo II. Una vez conseguido el goteo de liquido cefaloraquideo se administro lidocaina al 5 porciento 1 mg/kg/p. No se recomendò ninguna medida especial para el postoperatorio. A las 48 horas de la punción se interrogo a los pacientes para verificar si presentò cafelea. Resultados. Se observo una cefalea del 10 porciento para el grupo I, minetras que para el grupo II no se prsentò cefalea en ningun caso


Assuntos
Humanos , Masculino , Feminino , Adulto , Urologia/instrumentação , Ginecologia/instrumentação , Anestesia Epidural/enfermagem , Cirurgia Colorretal/instrumentação , Traumatologia/instrumentação , Agulhas/normas , Líquido Cefalorraquidiano/fisiologia
15.
Professional Medical Journal-Quarterly [The]. 1995; 2 (1): 63-7
em Inglês | IMEMR | ID: emr-39335

RESUMO

The study was designed to know the incidence of Headache during seven days after spinal anaesthesia. Disposable spinal needles of two standard gauges [No. 22 and No. 20] were used on two groups of patients. It was found that incidence of post spinal headache is more in that group of patients, in which wide bore needles [No. 20] were used for the dural puncture and subsequent analgesia


Assuntos
Raquianestesia/efeitos adversos , Agulhas/normas , Anestesia
16.
Dermatología (Santiago de Chile) ; 10(1): 69-74, 1994. tab, ilus
Artigo em Espanhol | LILACS | ID: lil-136177

RESUMO

Las características principales de una sutura ideal es que sea fuerte, fácilmente manipulable, nudo seguro, mínima reactividad tisular, que no favorezca infecciones y que no sea costosa. Los materiales de sutura son clasificados y se propone el buen uso de ellos en la cirugía dermatológica para obtener los mejores resultados


Assuntos
Humanos , Equipamentos Cirúrgicos/normas , Suturas/normas , Categute/normas , Agulhas/normas
17.
Arch. argent. dermatol ; 43(6): 419-24, nov.-dic. 1993. ilus
Artigo em Espanhol | LILACS | ID: lil-129862

RESUMO

El cierre de las heridas sometidas a alguna tensión obliga a la utilización de las suturas apropiadas, a efectos de evitar cicatrices anchas o dehiscencias. Se describen diversos tipos de puntos profundos, también llamados intradérmicos, y las diferentes variantes de puntos de colchonero, así como los materiales más apropiados para realizarlos


Assuntos
Humanos , Pele/cirurgia , Suturas/normas , Técnicas de Sutura/instrumentação , Agulhas/normas , Técnicas de Sutura , Técnicas de Sutura/normas
18.
Artigo em Inglês | IMSEAR | ID: sea-42145

RESUMO

Re-usable glass and disposable plastic syringes and needles were tested for their sterility. Ninety-one re-usable glass, 111 disposable plastic syringes, 105 re-usable and 91 disposable needles were determined for microbial contamination by direct method using soy-bean-casein digest and fluid thioglycolate media. The positive results were 2.2 per cent (2/91), 0.9 per cent (1/111), 2.9 per cent (3/105) and 3.3 per cent (3/91) for re-usable and disposable syringes and needles, respectively. It is concluded that there is no difference in the rates of contamination of re-usable and disposable items.


Assuntos
Bactérias/isolamento & purificação , Equipamentos Descartáveis/normas , Equipamentos Médicos Duráveis , Contaminação de Equipamentos , Hospitais , Agulhas/normas , Esterilização , Seringas/normas , Tailândia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA